Fixed Quantity Oil Supply Valve
Feature
1. Unlike existing HMV, this quantitative valve supplies oil only after pump stops operating.
2. Depending on oil supply system, it is possible to be used in combination with HMV. Also, oil supply up to 0.1~1.0cc is possible just by replacing nipple.
※ Order Method
▶ When you need 0.1 - 0.3 - 0.4 - 0.6 - 1.0(cc)from left while using five ports - Order number HMLV-5-0103040610
SPEC
| Number of outlet | Operating Pressure | Reset Pressure |
HMLV-2 | 2 | 10kg/cm² | 3kg/cm² |
HMLV-3 | 3 | ||
HMLV-5 | 5 |
Code No. | 01 | 02 | 03 | 04 | 06 | 10 |
---|---|---|---|---|---|---|
Volume(cc/st.) | 0.1 | 0.2 | 0.3 | 0.4 | 0.6 | 1.0 |
Marking | 01 | 02 | 03 | 04 | 06 | 10 |
Operating Guide
1. Once pump begins operating, oil fills up the front part of the distributor piston.
2. Oil with pressure of 10-20kg/cm² in the main pipe pushes the piston within the cylinder to fill up desired quantity of oil.
3. When pump stops and the pressure in the main pipe is released, the piston supplies lubricant oil through the spring pressure and repeats this operation.
External Figure