Feature
1. HCP-□HMF(S)
· Identical pump spray areas make exchanges easy.
· Prolonged idling is prohibited due to the installed mechnical seal. (Idling for more than 10 seconds is prohibited)
· It is produced with a single-unit shaft, which increases durability and makes management easy.
2. HCP-□EHMF(S)
· High efficiency motor is installed in HCP-HMF(S) Type
· Excellent electricity savings and high economic return on investment through optimized efficiency
· Increase in life-time use through slow temperature increase and use of highly energy-efficient energy materials.
· Acquired high efficiency energy equipment mark.
Pump Spec
| MOTOR | PUMP | |||||||
OUTPUT (W) | FREQUENCY(Hz) | VOLTAGE (V) | CURRENT (A) | PHASE | POLES | TOTAL HEAD(m) | DIS. VOL ( l /min) | PIPE SIZE(PT) | |
HCP-1100EHMF(S) | 1100 | 50 | 220 380 | 4.3 2.5 | 3 | 2 | 30 | 30 | 3/4" |
60 | 200/220 380 | 5.1 3.0 | 45 | ||||||
HCP-1800EHMF(S) | 1800 | 50 | 200 380 | 6.5 3.8 | 3 | 2 | 50 | 30 | 3/4" |
60 | 200/220 380 | 7.0 4.1 | 70 | ||||||
HCP-2500EHMF(S) | 2500 | 50 | 200 380 | 8.7 5.2 | 3 | 2 | 70 | 30 | 3/4" |
60 | 200/220 380 | 9.7 5.6 | 100 | ||||||
HCP-4000EHMF(S) | 4000 | 50 | 200 380 | 16.0 8.5 | 3 | 2 | 90 | 20 | 3/4" |
60 | 200/220 380 | 18.0 10.7 | 130 |
Packing Spec
MODEL NAME | PACKING SIZE(cm) | WEIGHT(kg) | |
---|---|---|---|
PUMP | PACKING | ||
HCP-1100EHMF | 50(W) x 30(L) x 27(D) | 26 | 27 |
HCP-1100EHMFS | 25 | 27 | |
HCP-1800EHMFS | 28 | 29 | |
HCP-1800EHMF | 63(W) x 29(L) x 30(D) | 29 | 30 |
HCP-2500EHMF | 39 | 40 | |
HCP-2500EHMFS | 38 | 39 | |
HCP-4000EHMF | 45 | 46 | |
HCP-4000EHMFS | 44 | 45 |
Performance Curve
* When using non water-soluble cutting fluid, Viscosity must be under 32cSt. Pump performance (pressure and quantity) will decrease compared to water-solube cutting fluid.
External Figure
Dimension