Internal & External Control Proportional Oil Supply Pump
Feature
1. It is the most suitable pump for proportional oil supply. It can be applied to a wide range of industrial machines.
2. The compact design reduces installation space limitations, and the simple use means easy installation and repairs
3. During reduced ulage, selections can be made to suit user environments using contact output and buzzer.
4. Every model is attached with a suction filter to prevent the entry of alien substances in the pipe.
5. Increased pressure settings are available according to operational environments.
6. Internal control type(HMGP-105N, 105M, 103) and External control type(HMGP-105C) can be used.
PUMP SPEC
PUMP SPEC | |||||
---|---|---|---|---|---|
MODEL NAME | HMGP-105N | HMGP-105M | HMGP-103 | HMGP-105C | |
PUMP TYPE | GEAR PUMP | ||||
DISCHARGE PRESSURE | 8kg/cm² | ||||
USING OIL | 32~220(cSt) | ||||
FILTER | 80 Mesh | ||||
TANK CAPACITY | 2Liter | ||||
DISCHARGE AMOUNT | 4~80cc | 4~50cc | 3~30 / 4~80cc | 100cc/min | |
INTERVAL TIME | 300~120min | 300~120min | External control | ||
FLOAT S/W | - | Contact type A contact (NO) | |||
- | ON at Low level | ||||
OIL WARNING | Order specification | BUZZER | Optput at Contact point | ||
MOTOR SPEC | |||||
INPUT | 50W | ||||
PHASE | 1Ø | ||||
VOLTAGE | 110V | 200V | 220V | ||||
CURRENT | 1.15A/0.95A | 0.60A | 0.75A/0.5A | ||||
FREQUENCY | 50/60Hz | ||||
PACKING SPEC | |||||
PACKING SIZE(cm) | 15(W) x 18(L) x 26(D) | ||||
WEIGHT(kg) | PUMP | 2.4 | |||
PACKING | 2.5 |
Components
External Figure
Operating Guide
1. The pump operates once power is connected and electricity is supplied You can set the pause time using the Interval ① on the front of the pump, and discharge
② to set the operating time (seconds). Afterwards, the pump will repeatedly operate and pause.
2. Minimum pause time of the pump is 3 minutes, and the minimum discharge time can be set to 3cc.(The pause time is divided into 3-30 minutes for Stype, and 30-120 minutes for the L type.)
3. When operating the pump, the DIS, lamp ③ switches on, and during the pause, the INT. lamp ④ switches on.
4. The MAN, button ⑤ can be used for test operations and to let air out from the pipes. (But, do not operate more than 5 minutes, as it can cause motor damage)
5. The pump is set at 8kg/cm when released from the factory, but this may differ depending on the changes in the viscosities of the oils used oil viscosity, surrounding temperature).
Hydraulic circuit drawing
| Wiring Diagram
|