LOGO

HWANGHAE ELECTRIC

Air gab brake motor and fan manufacturer, Ring blower, Small high speed blower, Turbo blower and more
Name

RING BLOWER

Model HRB-1102, HRB-1102MP, HRB-1202, HRB-1202MP
Series RING BLOWER
Catalog CATALOG-HWANGHAE_ELECTRIC-RING_BLOWER-OOsATE2.pdf
Product Description

HRB-1102, HRB-1102MP, HRB-1202, HRB-1202MP  Three Phase [3Ø]


- The allowable Tolerance of dimension is ± 5mm.
- The dimension can be changed for improvement without notice


Performance & Specifications

The blower with the name suffix MH (Motor High-efficiency) is designed to run at 60Hz. 

HRB-1102MP

HRB-1102

HRB-1202MP

HRB-1202

50Hz

60Hz

50Hz

60Hz

50Hz

60Hz

50Hz

60Hz

PHASE

3

3

3

3

MOTOR

HP

-

16.8

15.0

16.8

-

23.0

20.0

23.0

Kw

-

12.6

11.0

12.6

-

17.3

15.0

17.3

PRESSURE

mmAq

-

6200

5500

6200

-

7200

6500

7200


VACUUM

mmAq

-

4300

4000

4300

-

4800

4500

4800


MAX .

AIR FLOW

㎥/min

-

9.5

8.0

9.5

-

9.5

8.0

9.5

CURRENT

220V

A

-

45.0

40.0

50.2

-

50.2

40.7

56.0

380V

A

-

26.0

23.1

29.0

-

29.0

23.5

32.3

SOUND LEVEL

dB(A)

82

82

82

82

MATERIAL

IMPELLER

Aluminum

Aluminum

Aluminum

Aluminum

CASING

Cast Iron

Cast Iron

Cast Iron

Cast Iron

BEARING

FRONT

6207ZC3

6207ZC3

6207ZC3

6207ZC3

MIDDLE

-

-

-

-

REAR

6308ZC3

6308ZC3

6308ZC3

6308ZC3

WEIGHT

Kg

240

240

250

250


STARTING CLASS

K

K

K

K


INSULATION CLASS

F

F

F

F


- The performances above were measured under conditions of air temperature 20 °C and atmospheric pressure 1,013mbar.
- The allowable tolerance of the performance value is +10%
- The sound level was measured at a distance of 1.5m with the fully open inlet and outlet ports.
-  Anti-corrosive and explosion-proof treatments can be applied upon request.



Performance Curve


- The continuous operation can be made at a point below the curve, however, the continuous operation nearby the rated pressure point may cause a motor breakdown. 

   In the case of the continuous operation close to the rated pressure, it is strongly recommended to use the pressure-relief valve. See accessories, page 61.

- The allowable tolerance of the performance value is ± 10%

Products of HWANGHAE ELECTRIC