HRB-102, HRB-202, HRB-202MP, HRB-302, HRB-302MP Three Phase [3Ø]
- The allowable Tolerance of dimension is ± 5mm.
- The dimension can be changed for improvement without notice
Performance & Specifications
The blower with the name suffix MH (Motor High-efficiency) is designed to run at 60Hz.
| HRB-102 | HRB-202MP | HRB-202 | HRB-302MP | HRB-302 | |||||||
50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | |||
PHASE | 3 | 3 | 3 | 3 | 3 | |||||||
MOTOR | HP | 0.5 | 0.7 | - | 1.2 | 1.0 | 1.2 | - | 2.0 | 1.5 | 2.0 | |
Kw | 0.4 | 0.5 | - | 0.93 | 0.75 | 0.93 | - | 1.5 | 1.1 | 1.5 | ||
PRESSURE | mmAq | 1200 | 1500 | - | 2500 | 2000 | 2500 | - | 3000 | 2700 | 3000 | |
VACUUM | mmAq | 1000 | 1000 | - | 2000 | 1500 | 2000 | - | 2200 | 2000 | 2200 | |
MAX . AIR FLOW | ㎥/min | 1.4 | 1.65 | - | 1.65 | 1.4 | 1.65 | - | 1.65 | 1.4 | 1.65 | |
CURRENT | 220V | A | 2.4 | 2.6 | - | 4.2 | 4.0 | 4.2 | - | 4.8 | 4.8 | 5.2 |
380V | A | 1.4 | 1.5 | - | 2.4 | 2.3 | 2.4 | - | 2.8 | 2.8 | 3.0 | |
SOUND LEVEL | dB(A) | 68 | 68 | 68 | 68 | 68 | ||||||
MATERIAL | IMPELLER | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | ||||||
CASING | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | |||||||
BEARING | FRONT | 6203ZC3 | 6203ZC3 | 6203ZC3 | 6203ZC3 | 6203ZC3 | ||||||
MIDDLE | - | - | - | - | - | |||||||
REAR | 6203ZZC3 | 6203ZZC3 | 6203ZZC3 | 6203ZZC3 | 6203ZZC3 | |||||||
WEIGHT | Kg | 15 | 18 | 18 | 20 | 20 | ||||||
STARTING CLASS | K | K | K | K | K | |||||||
INSULATION CLASS | F | F | F | F | F |
- The performances above were measured under conditions of air temperature 20 °C and atmospheric pressure 1,013mbar.
- The allowable tolerance of the performance value is +10%
- The sound level was measured at a distance of 1.5m with the fully open inlet and outlet ports.
- Anti-corrosive and explosion-proof treatments can be applied upon request.
Performance Curve
- The continuous operation can be made at a point below the curve, however, the continuous operation nearby the rated pressure point may cause a motor breakdown.
In the case of the continuous operation close to the rated pressure, it is strongly recommended to use the pressure-relief valve. See accessories, page 61.
- The allowable tolerance of the performance value is ± 10%