HRB-500, HRB-500MP, HRB-600, HRB-600MP, HRB-700, HRB-700MP Three Phase [3Ø]
- The allowable Tolerance of dimension is ± 5mm.
- The dimension can be changed for improvement without notice
Performance & Specifications
The blower with the name suffix MH (Motor High-efficiency) is designed to run at 60Hz.
| HRB-500MP | HRB-500 | HRB-600MP | HRB-600 | HRB-700MP | HRB-700 | ||||||||
50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | |||
PHASE | 3 | 3 | 3 | 3 | 3 | 3 | ||||||||
MOTOR | HP | - | 3.4 | 3.0 | 3.4 | - | 5.0 | 4.0 | 5.0 | - | 6.0 | 5.3 | 6.0 | |
Kw | - | 2.55 | 2.2 | 2.55 | - | 3.7 | 3.0 | 3.7 | - | 4.5 | 4.0 | 4.5 | ||
PRESSURE | mmAq | - | 2000 | 2200 | 2000 | - | 3000 | 2800 | 3000 | - | 3400 | 3300 | 3400 | |
VACUUM | mmAq | - | 2200 | 2300 | 2200 | - | 2800 | 2600 | 2800 | - | 3300 | 3200 | 3300 | |
MAX . AIR FLOW | ㎥/min | - | 6.0 | 5.0 | 6.0 | - | 6.0 | 5.0 | 6.0 | - | 6.0 | 5.0 | 6.0 | |
CURRENT | 220V | A | - | 12.1 | 13.0 | 12.1 | - | 12.6 | 13.5 | 14.0 | - | 17.0 | 16.6 | 17.0 |
380V | A | - | 7.0 | 7.5 | 7.0 | - | 7.3 | 7.8 | 8.1 | - | 9.8 | 9.6 | 9.8 | |
SOUND LEVEL | dB(A) | 76 | 76 | 76 | 76 | 76 | 76 | |||||||
MATERIAL | IMPELLER | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | |||||||
CASING | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | ||||||||
BEARING | FRONT | 6206ZC3 | 6206ZC3 | 6206ZC3 | 6206ZC3 | 6206ZC3 | 6206ZC3 | |||||||
MIDDLE | - | - | - | - | - | - | ||||||||
REAR | 6205ZC3 | 6205ZC3 | 6205ZC3 | 6205ZC3 | 6205ZC3 | 6205ZC3 | ||||||||
WEIGHT | Kg | 38 | 38 | 42 | 42 | 46 | 46 | |||||||
STARTING CLASS | K | K | K | K | K | K | ||||||||
INSULATION CLASS | F | F | F | F | F | F |
- The performances above were measured under conditions of air temperature 20 °C and atmospheric pressure 1,013mbar.
- The allowable tolerance of the performance value is +10%
- The sound level was measured at a distance of 1.5m with the fully open inlet and outlet ports.
- Anti-corrosive and explosion-proof treatments can be applied upon request.
Performance Curve
- The continuous operation can be made at a point below the curve, however, the continuous operation nearby the rated pressure point may cause a motor breakdown.
In the case of the continuous operation close to the rated pressure, it is strongly recommended to use the pressure-relief valve. See accessories, page 61.
- The allowable tolerance of the performance value is ± 10%