HRB-1110, HRB-1110MP Three Phase [3Ø]
- The allowable Tolerance of dimension is ± 5mm.
- The dimension can be changed for improvement without notice
Performance & Specifications
The blower with the name suffix MH (Motor High-efficiency) is designed to run at 60Hz.
| HRB-1110MP | HRB-1110 | ||||
50Hz | 60Hz | 50Hz | 60Hz | |||
PHASE | 3 | 3 | ||||
MOTOR | HP | - | 11.5 | 10.0 | 11.5 | |
Kw | - | 8.6 | 7.5 | 8.6 | ||
PRESSURE | mmAq | - | 2200 | 1300 | 2200 | |
VACUUM | mmAq | - | 1800 | 1300 | 1800 | |
MAX . AIR FLOW | ㎥/min | - | 18.0 | 14.0 | 18.0 | |
CURRENT | 220V | A | - | 28.9 | 18.2 | 29.0 |
380V | A | - | 16.7 | 10.5 | 16.7 | |
SOUND LEVEL | dB(A) | 82 | 82 | |||
MATERIAL | IMPELLER | Aluminum | Aluminum | |||
CASING | Cast Iron | Cast Iron | ||||
BEARING | FRONT | 6208ZC3 | 6208ZC3 | |||
MIDDLE | - | - | ||||
REAR | 6308ZC3 | 6308ZC3 | ||||
WEIGHT | Kg | 239 | 239 | |||
STARTING CLASS | H | H | ||||
INSULATION CLASS | F | F |
- The performances above were measured under conditions of air temperature 20 °C and atmospheric pressure 1,013mbar.
- The allowable tolerance of the performance value is +10%
- The sound level was measured at a distance of 1.5m with the fully open inlet and outlet ports.
- Anti-corrosive and explosion-proof treatments can be applied upon request.
Performance Curve
- The continuous operation can be made at a point below the curve, however, the continuous operation nearby the rated pressure point may cause a motor breakdown.
In the case of the continuous operation close to the rated pressure, it is strongly recommended to use the pressure-relief valve. See accessories, page 61.
- The allowable tolerance of the performance value is ± 10%