HRB-1000, HRB-1000MP Three Phase [3Ø]
- The allowable Tolerance of dimension is ± 5mm.
- The dimension can be changed for improvement without notice
Performance & Specifications
The blower with the name suffix MH (Motor High-efficiency) is designed to run at 60Hz.
| HRB-1000MP | HRB-1000 | ||||
50Hz | 60Hz | 50Hz | 60Hz | |||
PHASE | 3 | 3 | ||||
MOTOR | HP | - | 16.8 | 15.0 | 16.8 | |
Kw | - | 12.6 | 11.0 | 12.6 | ||
PRESSURE | mmAq | - | 5000 | 4400 | 5000 | |
VACUUM | mmAq | - | 3500 | 3500 | 3500 | |
MAX . AIR FLOW | ㎥/min | - | 10.0 | 8.4 | 10.0 | |
CURRENT | 220V | A | - | 45.0 | 40.0 | 40.0 |
380V | A | - | 26.0 | 23.1 | 23.1 | |
SOUND LEVEL | dB(A) | 78 | 78 | |||
MATERIAL | IMPELLER | Aluminum | Aluminum | |||
CASING | Cast Iron | Cast Iron | ||||
BEARING | FRONT | 6207ZC3 | 6207ZC3 | |||
MIDDLE | - | - | ||||
REAR | 6308ZC3 | 6308ZC3 | ||||
WEIGHT | Kg | 190 | 190 | |||
STARTING CLASS | H | H | ||||
INSULATION CLASS | F | F |
- The performances above were measured under conditions of air temperature 20 °C and atmospheric pressure 1,013mbar.
- The allowable tolerance of the performance value is +10%
- The sound level was measured at a distance of 1.5m with the fully open inlet and outlet ports.
- Anti-corrosive and explosion-proof treatments can be applied upon request.
Performance Curve
- The continuous operation can be made at a point below the curve, however, the continuous operation nearby the rated pressure point may cause a motor breakdown.
In the case of the continuous operation close to the rated pressure, it is strongly recommended to use the pressure-relief valve. See accessories, page 61.
- The allowable tolerance of the performance value is ± 10%