HRB-802, HRB-802MP, HRB-902, HRB-902MP. HRB-1002, HRB-1002MP Three Phase [3Ø]
- The allowable Tolerance of dimension is ± 5mm.
- The dimension can be changed for improvement without notice
Performance & Specifications
The blower with the name suffix MH (Motor High-efficiency) is designed to run at 60Hz.
| HRB-802MP | HRB-802 | HRB-902MP | HRB-902 | HRB-1002MP | HRB-1002 | ||||||||
50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | |||
PHASE | 3 | 3 | 3 | 3 | 3 | 3 | ||||||||
MOTOR | HP | - | 6.0 | 5.3 | 6.0 | - | 8.4 | 7.5 | 8.4 | - | 11.5 | 10.0 | 11.5 | |
Kw | - | 4.5 | 4.0 | 4.5 | - | 6.3 | 5.5 | 6.3 | - | 8.6 | 7.5 | 8.6 | ||
PRESSURE | mmAq | - | 3700 | 3500 | 3700 | - | 5200 | 5000 | 5200 | - | 6000 | 5500 | 6000 | |
VACUUM | mmAq | - | 3500 | 3000 | 3500 | - | 4300 | 4000 | 4300 | - | 4500 | 4300 | 4500 | |
MAX . AIR FLOW | ㎥/min | - | 6.1 | 5.2 | 6.1 | - | 6.1 | 5.2 | 6.1 | - | 6.1 | 5.2 | 6.1 | |
CURRENT | 220V | A | - | 20.0 | 17.0 | 17.0 | - | 26.8 | 22.0 | 22.0 | - | 34.7 | 31.21 | 31.2 |
380V | A | - | 11.5 | 9.8 | 9.8 | - | 15.5 | 12.7 | 12.7 | - | 20.0 | 18.0 | 18.0 | |
SOUND LEVEL | dB(A) | 80 | 80 | 80 | 80 | 80 | 80 | |||||||
MATERIAL | IMPELLER | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | |||||||
CASING | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | ||||||||
BEARING | FRONT | 6206ZC3 | 6206ZC3 | 6206ZC3 | 6206ZC3 | 6206ZC3 | 6206ZC3 | |||||||
MIDDLE | 6007ZC3 | 6007ZC3 | 6207ZC3 | 6207ZC3 | 6207ZC3 | 6207ZC3 | ||||||||
REAR | 6305ZC3 | 6305ZC3 | 6208ZC3 | 6208ZC3 | 6208ZC3 | 6208ZC3 | ||||||||
WEIGHT | Kg | 57 | 57 | 81 | 81 | 104 | 104 | |||||||
STARTING CLASS | K | K | K | K | K | K | ||||||||
INSULATION CLASS | F | F | F | F | F | F |
- The performances above were measured under conditions of air temperature 20 °C and atmospheric pressure 1,013mbar.
- The allowable tolerance of the performance value is +10%
- The sound level was measured at a distance of 1.5m with the fully open inlet and outlet ports.
- Anti-corrosive and explosion-proof treatments can be applied upon request.
Performance Curve
- The continuous operation can be made at a point below the curve, however, the continuous operation nearby the rated pressure point may cause a motor breakdown.
In the case of the continuous operation close to the rated pressure, it is strongly recommended to use the pressure-relief valve. See accessories, page 61.
- The allowable tolerance of the performance value is ± 10%