HRB-102/1, HRB-202/1, HRB-302/1 Single Phase [1Ø]
- The allowable Tolerance of dimension is ± 5mm.
- The dimension can be changed for improvement without notice
Performance & Specifications
| HRB-102/1 | HRB-202/1 | HRB-302/1 | |||||
50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | |||
PHASE | 1 | 1 | 1 | |||||
MOTOR | HP | 0.4 | 0.5 | 0.85 | 1.0 | 1.2 | 1.5 | |
Kw | 0.33 | 0.4 | 0.63 | 0.75 | 0.9 | 1.1 | ||
PRESSURE | mmAq | 1200 | 1200 | 2100 | 2100 | 2100 | 2500 | |
VACUUM | mmAq | 1000 | 1000 | 1700 | 1700 | 2000 | 2000 | |
MAX . AIR FLOW | ㎥/min | 1.4 | 1.65 | 1.4 | 1.65 | 1.4 | 1.65 | |
CURRENT | 220V | A | 3.6 | 3.8 | 4.4 | 5.3 | 4.8 | 6.0 |
SOUND LEVEL | dB(A) | 68 | 68 | 68 | ||||
MATERIAL | IMPELLER | Aluminum | Aluminum | Aluminum | ||||
CASING | Aluminum | Aluminum | Aluminum | |||||
BEARING | FRONT | 6203ZC3 | 6203ZC3 | 6203ZC3 | ||||
MIDDLE | - | - | - | |||||
REAR | 6203ZZC3 | 6203ZZC3 | 6203ZZC3 | |||||
WEIGHT | Kg | 18 | 20 | 23 | ||||
INSULATION CLASS | F | F | F |
- The performances above were measured under conditions of air temperature 20 °C and atmospheric pressure 1,013mbar.
- The allowable tolerance of the performance value is +10%
- The sound level was measured at a distance of 1.5m with the fully open inlet and outlet ports.
- Anti-corrosive and explosion-proof treatments can be applied upon request.
Performance Curve
- The continuous operation can be made at a point below the curve, however, the continuous operation nearby the rated pressure point may cause a motor breakdown.
In the case of the continuous operation close to the rated pressure, it is strongly recommended to use the pressure-relief valve. See accessories, page 61.
- The allowable tolerance of the performance value is ± 10%