Strong Point
1. Flux fume generated during reflow process normally cannot release and remain inside furmaces.
Heat exchange unit located side wall for each furmace makes fume cool down and as liquid, and draw flux liquid to bottle for easy maintenance.
2. Operations can be done by PC, separeted from switch board.
3. Various differences in temperature between the device are decreased by hot air circulation heating of the up- down turbo fan.
4. A setup by the free combination of the pre-heating part and the re-flowing part is possible by the 8zones furnace composition.
5. Wide setup range by setting up each zone up-down heating temperatures independently.
Main Specifications (ITM-3007LF) | |||
No. | ITEM | SPECIFICATION | |
1 | PCB SIZE | MIN | 50(W)*70(L)mm*0.6t |
MAX | 300(W)*330(L)mm*2.0t | ||
2 | Componet max hight | 上, 下 20mm | |
3 | Furnace | 上, 下 8 Zone | |
4 | Upper Heater | 220v 1Ø 3.7Kw | |
5 | Lower Heater | 220v 1Ø 3.7Kw | |
6 | PC | Standard | |
7 | The movement direction | Left → Right | |
8 | FL : PCB entrance Hight | 900 ±20mm | |
9 | Carrying conveyor | 0.5~1.5m/min | |
10 | Power supply | 3相 220v 60Hz 65.5Kw | |
11 | Dried air pressure | More than 4~5kg f/㎠ | |
12 | Dimension | 4950(L)*1350(W)*1445(H) | |
13 | Total net weight | 2500Kg | |
14 | Type | Stand-by Type | |
15 | Option | Center Bar UPS |