◆ Description
> Put a work in vacuum chamber and fill Helium gas by pressure. Then, the leak of Helium gas can be measured by detector if the work is cracked(Possible to detect Micro Leak)
◆ Main Specification
MODEL | Lift & Carry Type | |
C/TIME | 40sec/EA | |
PROCESS | LOADING | Roller C/V & Escaper of all process |
HOT BLOWING | Drying of work surface-Improvement of vacuum effects | |
Equipted the electric heater | ||
AIR LEAK TEST | Leak Detection by 1st Air Leak Tester(Pressurizer Type) | |
- COSMO Detector | ||
HE LEAK TESTER |
Micro Leak Detection by 2nd He Leak Detector | |
Work Vacuum 10 Torr : 10sec | ||
He gas pressure 15kg/㎠ : 3sec | ||
Detection : 25sec (Leak Late : 1.3*10-8pa.㎥/sec) | ||
He Gas Collection(85% and more) : 3sec | ||
Work withdraw(vacuum purge) : 2sec |