Normally, the case of submerged cargo pump installed vessel, heating coil is not installed in the cargo tank. Instead of it, cargo deck heater can be installed at the deck of the vessel. Therefore, it makes a condition to pump the fluid in the cargo tank.
Characteristics
▣ Advantage
Easy Installation & Labor cost saving
Easy Maintenance
Saving Energy
Free from the cargo damage
Rigid structure against vibration
▣ Cargo Deck Heater Data
Heat capacity for HFO No.6 | KCH – 200 200kw at 50㎥/h Saturated steam at 7bar / 170℃ |
KCH – 360 360kw at 80㎥/h Saturated steam at 7bar / 170℃ |
KCH – 500 500kw at 180㎥/h Saturated steam at 7bar / 170℃ |
KCH – 700 700kw at 200㎥/h Saturated steam at 7bar / 170℃ |
KCH – 1250 1250kw at 300㎥/h Saturated steam at 7bar / 170℃ |
Max. P/Temp. Cargo side | 15.7bar / 100℃ | 15.7bar / 100℃ | 15.7bar / 100℃ | 15.7bar / 100℃ | 15.7bar / 100℃ |
Max. P/Temp. Heating medium side |
9.8bar / 185℃ | 9.8bar / 185℃ | 9.8bar / 185℃ | 9.8bar / 185℃ | 9.8bar / 185℃ |
Length of steam element plate | 1078mm | ||||
Number of elements | 16EA | 22EA | 24EA | 36EA | 54EA |
Heating surface | 5.3㎡ | 7.7㎡ | 8.4㎡ | 12.4㎡ | 17.8㎡ |
Material | 316L | ||||
Heating medium type | Saturated steam or Hot water | ||||
“TW” Total Width | 700mm | 800mm | 800mm | ||
“W” Width | ¢ 406.4mm | ¢ 508.0mm | ¢ 508.0mm | ||
“H1” Height | 175mm | 222mm | 222mm | ||
“H2” Height | 139.1mm | 1401.2mm | 1401.2mm | ||
“H3” Height | 1686mm | 1925mm | 1925mm | ||
Total weight dry heater | 336kg | 365kg | 464kg | 498kg | 550kg |
Cover weight | 82kg | 82kg | 91kg | 91kg | 91kg |