Medical equipment manufacturer, Patient monitoring unit, Aritificial respirator, Ventilator, Pulse oximeter and more
Model MV2000
Series Ventilator
Product Description

 

SU:M Series Aims to Help Successful Weaning

 
MEKICS understands a modern respiratory care system which demands  not only basic ventilation modes but also advanced functions for  successful  weaning  of  patient  and  for  supporting  clinician  as  well.

 
SU:M Series system becomes complete with useful functions for  successful and adaptive weaning function and assistant functions in  acute respiratory care such as Hemo Dynamics (SpO2, EtCO2) and Lung  mechanics. Additionally, HFV mode of SU:M Series could provide the  possibility of a new successful story from premature to adult patient  with or without Extra-Corporeal Membrane Oxygenation (ECMO).
 

One of major topics of Conventional Ventilator in ICU is successful  weaning. MEKICS understands that reducing patient’s Work of Breathing  (WOB) and mismatching between patient and device are key factors for  successful weaning in acute invasive ventilation. SU:M series have these  core functions and performance. It has technical solution for reducing  asynchrony too. 


SU:M Series meets the essential requirements on  performance, accuracy and high safety. The SU:M  Series ventilator complys with:

• CE0470

• KFDA

• ISO13485

• ISO9001

MEK-ICS  MV2000

 

Powerful Modes
 

The extendable strong configurations make SU:M Series  highly competitive.
Standard  :   PACV,  VACV,   PSIMV,  VSIMV,   SPONT, O2Stream®, tBi-level, PRVC, AutoVent®
Options : CPR, TCPL-AC, TCPL-SIMV, PRVC-SIMV, AwPRV,  HFV (SHFV, DHFV).
 

High Frequency Ventilation (HFV)
 

SU:M Series provides a high level of clinical performance for  all the clinical demands from conventional to high frequency  ventilation. MEKICS’ unique pneumatic technology extends  the applicability of SU:M Series to HFV without any  additional hardware apparatus. It has also possibility to extend the
 

Reliability and Easy maintenance
 

The pneumatic system of SU:M Series is MEKICS’ unique  technology and it makes a basis for all the strong features  such as unique High Frequency Ventilation and high reliabil-  ity. Sohware based modes makes easier upgrade for  customer demands. SU:M series provides easy maintenance process with PC viewer economically including spare parts. 
 

SU:M Series Configurations

MEK-ICS  MV2000 1

ACV : Assist Control Ventilation Pressure Control  Synch 
SIMV : ronized Intermittent Mandatory Ventilation
SPONT : Spontaneous Ventilation
PRVC : Pressure Regulated Volume Control
CPR : Cardiopulmonary Resuscitation
TCPL : Time Cycled Pressure limeted Ventilation
AwPRV : Airway Pressure Release Ventilation
HFV : High Frequency Ventilation

 

1. Dual High Frequency Ventilation


MEKICS’ unique principle of HFV has a couple of clinical  benefits. The first is that patient can be cared continu-  ously even without replacing the breathing circuit  between conventional mode and HFV mode. This  strong benefit helps safe and easy care.

The second is Dual Phase High Frequency Ventilation  (DHFV). It is a combined mode with CMV and HFV. The  CMV phase of DHFV could be used to intend either intermittent lung expansion or intermittent exhalation  under high frequency ventilation. The intermittent lung expansion works for insuVicient lung recruit process in  HFV with low MAP. On the other hand, intermittent lung  exhalation could have an eVect of improving insuVi-  cient CO2 ventilation and get measured EtCO2 in HFV  with high MAP.

MEK-ICS  MV2000 2

 

2. AutoVent®


AutoVent® mode of SU:M Series is to induct successful weaning depending on patient’s lung condition and patient  breathing eVort by adaptive reaction-controlled algorithm.  AutoVent® mode supports the optimal pressure controlled  tidal volume with calculated respiration rate. We believe  this mode is a possibly optimal solution to care patient’s  changing lung condition continuously.
A patient aher surgery without any specific lung disease, the  demand of patient’s breathing may change continuously.  AutoVent® mode could help clinician more concentrate on  patient-care than setting-device.

MEK-ICS  MV2000 3

 

3. SpO2, EtCO2 (Hemo Dynamics)


This option could provide information of metabolic-CO2 and SpO2 as the result of respiration. This information  could be useful to a clinician for patient care without independent gas monitoring system and for reducing  complete dependency on Arterial Blood Gas Analysis  (ABGA). Especially, it is intended to provide more useful and comprehensive clinical information from this  combination of CO2, SpO2 and flow information.

MEK-ICS  MV2000 4

 

4. Smart Weaning


Asynchrony in SIMV is a major challenge for successful  weaning process. The first mission is how to meet  patient’s respiratory demand with a set of volume and respiration rate. The second is how not to interrupt patient’s breathing eVorts. In other words, it means how to avoid fighting.
The principle of smart weaning is to support minimum- pressure level and to allow over set-volume continuously as patient’s demand increases in inhalation phase.
The inspiratory time is extended to detect expiratory start point(Ex-sense) not to interrupt the patient exhalation eVort.

MEK-ICS  MV2000 5