Manometer Manual

- The differential pressure gauge should be installed in the place where the around temperature is not more than 60℃ and there isn't excessive vibration
- The pressure delivery tube(sensing line) should be connected as much as necessary length and this distance has no effects on accuracy of the pressure indication until within about 75m If the indication of manometer is shaken too much by the effects of vibrating or pulsating pressure, the pressure delivery tubes should be fixed or the air chambers should be installed to proven such problems
- This differential pressure gauge has no effects on the accuracy of the instructions though is is installed in the necessary position horizontally or vertically, but-zero-point should be set by adjusting in every time.
- There are a pair of high & low pressure tabs, The bottom tab should be connected to the high pressure side with respect to the punching plate of the dust collector, and the top tap should be connected to the low pressure side.