RS ROOTS TYPE SUBMERSIBLE BLOWER
There is rare noise since noise is absorbed or decreased by installing it under water.
On the ground, because Suction Silencer and underwater cable only come out above, spacious area is not necessary. In are of possible flood, the problem can be prevented by installing Suction Silencer in a high position.
Specifications
PERFORMANCE TABLE |
||||||||||||||||
MODEL | R.P.M |
THEORY AIR VOLUME
|
AIR VOLUME Qs(m3/min) POWER La(kw)
|
|||||||||||||
0.1kg/cm2
|
0.2kg/cm2
|
0.3kg/cm2
|
0.4kg/cm2
|
0.5kg/cm2
|
0.6kg/cm2
|
0.7kg/cm2
|
||||||||||
Qs
|
La
|
Qs
|
La
|
Qs
|
La
|
Qs
|
La
|
Qs
|
La
|
Qs
|
La
|
Qs
|
La
|
|||
RS50 | 1750 | 2.77 |
2.51
|
1.17
|
2.35
|
1.48
|
2.20
|
1.80
|
2.07
|
2.08
|
1.97
|
2.38
|
1.88
|
2.69
|
1.81
|
3.00
|
3450 | 5.46 |
4.96
|
2.29
|
4.57
|
2.89
|
4.29
|
3.49
|
4.01
|
4.05
|
3.77
|
4.6
|
3.60
|
5.28
|
3.45
|
5.89
|
|
RS65 | 1750 | 3.98 |
3.48
|
1.55
|
3.31
|
2.20
|
3.16
|
2.85
|
3.04
|
3.52
|
2.93
|
4.10
|
2.85
|
4.75
|
2.78
|
5.35
|
3450 | 7.85 |
6.75
|
3.23
|
6.40
|
4.42
|
6.08
|
5.76
|
5.84
|
6.90
|
5.65
|
8.09
|
5.46
|
9.27
|
5.28
|
10.46
|
|
RS80 | 1750 | 7.90 |
6.63
|
2.81
|
6.26
|
4.20
|
5.94
|
5.41
|
5.64
|
6.60
|
5.94
|
5.41
|
5.64
|
6.60
|
5.36
|
7.81
|
3500 | 15.79 |
13.15
|
5.47
|
12.27
|
8.14
|
11.53
|
10.54
|
10.85
|
13.15
|
10.26
|
15.53
|
9.73
|
17.94
|
9.28
|
20.56
|
|
RS100 | 1750 | 9.87 |
8.46
|
3.31
|
8.03
|
4.09
|
7.72
|
6.38
|
7.42
|
7.91
|
7.12
|
9.50
|
6.86
|
11.1
|
6.65
|
12.5
|
3540 | 19.98 |
16.82
|
6.68
|
16.00
|
9.69
|
15.27
|
12.88
|
14.62
|
15.93
|
14.03
|
18.85
|
13.47
|
22.57
|
12.92
|
25.00
|
760mmHg, temperature 20`C, relative humidity 75% and 1.2kg/m3 of specific gravity amount.
2. The error of the indicated air flow is ±5%.
Product Features
1.ULTRA LOW NOISE
Since blower is installed under water, noise is absorbed and decreased. The problems caused by noise to be solved.
2.REPAIR
No abrasion because water does not contact in the part of rotation. And repair cost to be reduced because foreign matters will be not attached in the impeller.
3.MACHINERY ROOM
Unnecessary soundproofing construction cost and ventilation construction cost to be reduced. The space can be used usefully because only inhalation silencer and under-water cable come above the ground. Submersion can be prevented in the area which flood occurs frequently because inhalation silencer is installed highly.