Feature
voltage sweep, the output voltage fluctuation patterns, and freely programmable
- ROM running on the existing built-in call patterns
- Called by some modifications to the pattern ROM Run / Save
- Create a new pattern and run / save (up to 38 patterns, Resolution: 1mS, 10mV)
- Method on vector format patterns, ease of programming
• PROGRAMMABLE DC power of a normal functioning
- CV / CC / OVP / UVL / OCP
• RS-232/485 interface, built-in
• 16bit ADC / DAC Resolution adopted by the voltage and current settings / display
• voltage / current analog programming (0 ~ 5V / 0 ~ 10V or VR) Remote On / Off SPECIFICATION
Output
• Output Volt/Curr: 0 ~ 25VDC / 20A Max
• Ripple and Noise : Max 30 mVrms (CV/CC Mode)
• Setting Resolution(Serial Communication / OP Panel)
- Voltage : 10mV / 10mV
- Current : 1mA / 10mA
• Analog Programming and Output Control
- Voltage : 0~5V,0~10V,VR
- Current : 0~5V,0~10V,VR
- Output on/off control : contact pont,Open Collector,12~24V
• Error of measurement (Display)
- Voltage : ±10mV Max
- Current : ±20mA Max
• Safety Function : OVP,UVL,OCP,OTP
• Anolog Monitor Output : Voltage/Current (0~10V/FS)
• Status Contact Out: READY,RUN,FAULT,CC
Sequence Function
• Number of Sequence : 1 (CV Mode Only)
• Number of Step : 1 ~ 10 (Repeat Same Pattern, Max 65535 Separate )
• Step Time : 1 mS ~ [65535 × 65535]mS (Resolution 1mS)
• In-Step Operation : Constant or Sweep
• Repeat Number of Sequence : 1 ~ 65535
• Sequence Control : Start,Stop (Serial Communication or OP Panel)
• Sequence Pattern
- Factory Set : Max 255 Pattern (ROM)
- User Programming : Max 38 Pattern (EEPROM Write/Read)
Others
• Ration Input : 180 ~240VAC 47 ~ 63Hz
• Conditions for USE
- Conditions for USE : Temp. +5 ~ +35℃ , Hum. less than 85% RH
- Conditions for ARCHIVE : Temp. -10 ~ +50℃ , Hum. less than 95% RH
• Weight : 7.5Kg