The strong points of the product
ㆍBy installing the controller of which controls are convenient, anyone can easily operate it, and the operational condition of the portable air conditioner can be observed easily.
ㆍBy self-diagnosing the condition of the machine, when an abnormality occurs, the machine automatically gets stopped and protected. Also, the abnormalities are indicated on the controller.
ㆍOperations are smooth in high temperatures and high humidity, as well as pure surroundings.
Spec
Division | Unit | AMC-3000S | AMC-3000D | AMC-5000 |
Cooling Capacity | Kcal/h | 3250 | 3250 | 5250 |
BTU | 12000 | 16000 | 21000 | |
Power Specifications | 1PH 220V 60Hz | |||
Dimensions (W*D*H) | mm | 486*665*1080 | 486*665*1080 | 486*635*1265 |
Weight | kg | 67 | 67 | 89 |
Rated power consumption | KW | 1.35 | 1.35 | 2.45 |
Current consumption | A | 6.1 | 6.1 | 11.2 |
Air volume | CMM | 8 ~ 9 | 9 ~ 10 | 11 ~ 13 |
Condenser Water Vessel | ℓ | 18Liter (Common application) / Option:Drain pump | ||
Suction filter | Aluminum Mesh Filter | |||
Refrigerant | R-22 / Option:R-410A | |||
Power Cord(Type/length) | Plug Type(3m) / Option:user spec | |||
Outlet wind speed | m/s | 9~10 | 10~11 | 10.5~12 |
Outlet Air Temperature Gap | °C | 12~13 | ||
Operating Conditions | 25°C DB / 60% RH ~ 40°C DB / 40% RH | |||
Safety Devices | * High Pressure Sensing Switch * Evaporator Freeze protection sensor * Condensate Water level control sensor * Compressor Protection Thermo * Compressor Protection Delay timer |
Division | Unit | AMC-6300 | AMC-8000 |
Cooling Capacity | Kcal/h | 6300 | 5250 |
BTU | 12000 | 21000 | |
Power Specifications | 1PH 220V 60Hz | ||
Dimensions (W*D*H) | mm | 486*665*1080 | 486*635*1265 |
Weight | kg | 75 | 89 |
Rated power consumption | KW | 1.5 | 2.45 |
Current consumption | A | 6.8 | 11.2 |
Air volume | CMM | 8 ~ 9 | 11 ~ 13 |
Condenser Water Vessel | ℓ | 18Liter (Common application) / Option:Drain pump | |
Suction filter | Aluminum Mesh Filter | ||
Refrigerant | R-22 / Option:R-410A | ||
Power Cord(Type/length) | Plug Type(3m) / Option:user spec | Terminal Type(5m) | |
Outlet wind speed | m/s | 9~10 | 10.5~12 |
Outlet Air Temperature Gap | °C | 12~13 | |
Operating Conditions | 25°C DB / 60% RH ~ 40°C DB / 40% RH | ||
Safety Devices | * High Pressure Sensing Switch * Evaporator Freeze protection sensor * Condensate Water level control sensor * Compressor Protection Thermo * Compressor Protection Delay timer |
- The above specifications may change according to design changes.