-Why is an Oil Mist Collector
â· Employee Health
· Skin Problems > Water-insoluble : oil-acne or folliculate
> Water-soluble : dermatitis or skin burn
· Respiratory problems > Bronchial irritation (bronchitis), asthma,
hypersensitivity pneumonia ·
· Ontogenic factors |> Ontogenic factors to skin, esophagus, larynx, stomach, gall or urinary bladder, pancreas, etc.
â· Secondary Accidents
Adhering to machines or the factory floor, oil mist may cause secondary accidents such as slips and falls
â· Productivity Loss
Floating oil mist can generate unpleasant odors, causing breathing difficulty, which in turn may result in employee inattention and productivity loss
â· Environmental Contamination and Energy Waste
Oil mist exhaust may cause environmental contamination and increase heating and cooling costs
â· Influence on Machines
Oil mist may cause breakdown of electrical parts of machines
-Anyclean Features
Oil Mist Collector(id:3143410) Product details - View Oil Mist Collector from F.N.C Trading Co., Ltd. - EC21
[No Filter]
No filtering. Oil mist is condensed and separated by collision and centrifugal force
[High collecting efficiency]
More than 98% oil mist collection efficiency through condensation and centrifugal separation
[Membrane-coated After Filter]
After Filter demonstrates more than 99.5% efficiency and 1-year durability even when collecting cigarette smoke and fumes (After Filter optional)
[Simple and safe maintenance]
Easy assembly / disassembly and convenient maintenance due to toggle clamps and wing nut
-Anyclean Cross Section
-Anyclean Applications
â· Anyclean Applications
â Machine Tools
Lathe, grinder, MCT, electric discharge machine,
die-casting machine, heading machine, drilling machine, etc.
â Other
Washing devices and other mist-generating locations
Oil Mist Collector(id:3143410) Product details - View Oil Mist Collector from F.N.C Trading Co., Ltd. - EC21
-Anyclean Specifications
MODEL |
AC6000 |
AC11000 |
AC2000 |
INPUT |
220V / 60Hz / 3P (380/440V) order specification |
||
POWER (kW) |
0.4 |
0.75 |
1.5 |
REVOLUTION (RPM) |
3.,400 |
3,400 |
3,400 |
FLOW RATE (ã¥/min.) |
6 |
15 |
30 |
STATIC PRESSURE |
125 |
125 |
125 |
COLLECTING EFFICIENCY |
98% (99.5% with After Filter) |
||
SUCTION DIAMETER (mm) |
100 |
150 |
200 |
NOISE (dB) |
55 |
60 |
65 |
WEIGHT (kg) |
40 |
50 |
65 |
DIMENSIONS (mm) |
Ø420 X 600H(690H) |
Ø480 X 670H(760H) |
Ø540 X 830H(950H) |
-Dimensions
âStandards
MODEL |
D |
PCD |
H' |
h1' |
h2' |
N |
id |
AC6000 |
420 |
370 |
600 |
50 |
550 |
15A |
100 |
AC11000 |
480 |
430 |
670 |
50 |
620 |
15A |
150 |
AC20000 |
535 |
485 |
830 |
50 |
780 |
15A |
200 |
âOptional(with After)
MODEL |
D |
PCD |
H |
h1 |
h2 |
N |
id |
AC6000 |
420 |
370 |
690 |
50 |
640 |
15A |
100 |
AC11000 |
480 |
430 |
770 |
50 |
720 |
15A |
150 |
AC20000 |
535 |
485 |
950 |
50 |
900 |
15A |
200 |