Ozone lamp
sing high-purity quartz (over99.99% of Sio2), the output of the sterilizing ray (253.7nm) is identical with the germicidal lamp, but unlike the other general UV Lamp, it also produces ozone-generating UV rays of 184.9nm, enabling strong deodorization as well as the sterilization of the area to where UV ray cannot reach.
In? general, the ozone generation through high voltage electric discharging accompanies simultaneous production of pollution materials like Nox or Sox(Nitrogen Oxides), as well as safety problem following the application of high-voltage electricity. However, our products can produce ozone purely from the `light' , without co-generation of any polluing material, and by using a nominal A/C power source, it demonstrates excellent safety and diminishes noies from other components.
Ordering Code |
Wattage |
Lamp Length |
UV Output |
Ozone Gerneration |
Average Life time |
HUV-900 |
3 |
95 |
1.5 |
10 |
20,000 |
HUV-127 |
6 |
126 |
5.0 |
20 |
20,000 |
HUV-170 |
8 |
166 |
6.0 |
30 |
18,000 |
HUV-200 |
10 |
203 |
10.0 |
50 |
15,000 |
HUV-300 |
18 |
300 |
15.0 |
100 |
10,000 |
HUV-450 |
24 |
450 |
20.0 |
200 |
10,000 |
*Ultraviolet output=253.7nm
Nominal Life Cycle :
Under windless environmental condition of R.T :20 + / -5c and R.H : 45 + / -10%
While the lamp is continuously operate within a cycle of 3 minutes on and 2 minutes off using a power source of AC 220V / 50~60Hz nominal voltage.
The accumulated time should be over 15,000~20,000 Hr.
Germicidal lamp
Using high-purity quartz (over99.99% of Sio2), the main frequency is the sterilization ray (253.7nm). Among diverse wavelengths of ultraviolet rays, UV in 253.7nm wavelength has an extremely strong sterilization power, which is 1,600 times of direct daylight, and thus called the `sterilizing ray'.
The sterilization mechanism works with the sterilizing ray by being absorbed into Thymine Timing among DNA elements of the cell, and then destroys the DNA alignment thus killing the genetic function. The DNA structure which the determines genetic function being referred as the double helical structure. This UV ray penetrate into Thymine, which is one of 4 amino acids (Adenine, Guanine, Cytosine, Thymine) bridging between two helical structures of DNA, which then transforms it into a completely different gene which is unable to form portein material. Especially, as this reaction can be taken place instantaneously by `light ray' , this method provides much faster sterilization than other methods (chemical or high temperature treatment), as well as an advantage of not producing residual material.
Ordering Code | Wattage | Lamp Length (mm) |
UV Output (mW/Cm2) |
Average Life time (Hrs) |
HUV-G900 | 3 | 95 | 1.5 | 20,000 |
HUV-G127 | 6 | 126 | 5.0 | 20,000 |
HUV-G170 | 8 | 166 | 6.0 | 18,000 |
HUV-G200 | 10 | 203 | 10.0 | 15,000 |
HUV-G300 | 18 | 300 | 15.0 | 10,000 |
HUV-G450 | 24 | 450 | 20.0 | 10,000 |
*Ultraviolet output=253.7nm
Nominal Life Cycle :
Under windless environmental condition of R.T :20 + / -5c and R.H : 45 + / -10%
While the lamp is continuously operate within a cycle of 3 minutes on and 2 minutes off using a power source of AC 220V / 50~60Hz nominal voltage.
The accumulated time should be over 15,000~20,000 Hr.