Basic Specifications
Rating Condition : Continuous
Voltage Endurance : AC1500V for 1 Min.
Insulation Resistance : DC500V, 10M
Operating Temperature : 10~40℃
Humidity : 20~80%
Coil Insulation Class : F Class (155℃)
Hall Effect Device : Optional
Power Supply Requirement : Trapezoidal or Sinusoidal Signal 3-phase Brushless Amplifier
Performance Specifications
Model | Unit | SWL-PS10C | SWL-PS20C | SWL-PS30C | SWL-PS40C |
Continuous Force | [ N ] | 42.1 | 84.5 | 125.1 | 166.7 |
Max. Force | [ N ] | 126.3 | 253.5 | 375.3 | 500.1 |
Continuous Current | [ Arms ] | 2 | 2 | 2 | 2 |
Max. Current | [ Arms ] | 6.0 | 6.0 | 6.0 | 6.0 |
Electrical Power | [ W ] | 377.7 | 377.7 | 377.7 | 377.7 |
Power Loss | [ W ] | 23.2 | 45.8 | 68.4 | 91.5 |
Resistance (Line toLine) | [ Ω ] | 3.86 | 7.63 | 11.40 | 15.25 |
Inductance (Line toLine) | [ mH ] | 13.15 | 26.89 | 40.36 | 53.80 |
Force Constant (Kf) | [ N/Arms ] | 21.05 | 42.25 | 62.55 | 83.35 |
Back EMF Constant (Ke) | [ V/(m/sec)] | 7.12 | 14.14 | 21.04 | 27.97 |
Motor Constant | [ N/W^½ ] | 6.5 | 13.0 | 19.3 | 25.7 |
Electrical Time Constant | [ msec ] | 3.41 | 3.52 | 3.54 | 3.53 |
POLE Pitch | [ mm ] | 24.0 | 24.0 | 24.0 | 24.0 |
Normal Force | [ N ] | 210 | 410 | 610 | 810 |