1 - Conductor : Annealed Copper Wire (Tin plating, Nickel plating, Silver plating)
2 - Insulation : Fluoro Resin (FEP)
1. Description
FEP is the wire which is insulated by nonflammable fluoro resin on copper wire annealed by special material. FEP has been using for internal wiring of electric equpment
2. Feature
▶ Physical-chemical
1) Allowable Temperature : Up to 150℃ or 200℃ (Depends on UL style)
2) Superiority of chemical resistance under chemical circomstance
3) Superiority of workability under humidity circomstance, severe condition
4) Superiority of mechanical strength
5) Superiority of fire retardance (UL VW-1 Grade)
▶ Electrical
1) Rated Voltage : 300, 600 or 1,000V (Depends on UL style)
2) Test Voltage : 2,000V/min (Depends on UL style)
3. Approval Standard
▶ UL and CSA approved (File No. E120271)
▶ AWM 1330/1331/1332/1333/3239
Style |
Grade |
Conductor (AWG) |
Insulation Thickness (mm) |
|
Temperature (℃) |
Voltage (V) |
|||
1330 |
200 |
600 |
10 - 30 |
0.51 |
1331 |
150 |
600 |
4/0 - 30 |
0.51 |
1332 |
200 |
300 |
10 - 30 |
0.33 |
1333 |
150 |
300 |
10 - 30 |
0.33 |
3239 |
200 |
DC 10KV |
10 - 24 |
0.64 |
3239 |
200 |
DC 20KV |
10 - 24 |
1.15 |