Basic Specifications
Rating Condition : Continuous
Voltage Endurance : AC1500V for 1 Min.
Insulation Resistance : DC500V, 10M
Operating Temperature : 10~40℃
Humidity : 20~80%
Coil Insulation Class : F Class (155℃)
Hall Effect Device : Optional
Power Supply Requirement : Trapezoidal or Sinusoidal Signal 3-phase Brushless Amplifier
Air cooling available at no extra cost
Performance Specifications
Model | Unit | SWL-DE10 | SWL-DE20 | SWL-DE30 | SWL-DE40 |
Continuous Force | [ N ] | 300.9 | 610.9 | 902.8 | 1230.8 |
Max. Force | [ N ] | 902.8 | 1805.6 | 2708.5 | 3611.3 |
Continuous Current | [ Arms ] | 13.9 | 13.9 | 13.9 | 13.9 |
Max. Current | [ Arms ] | 41.6 | 41.6 | 41.6 | 41.6 |
Electrical Power | [ W ] | 2625.293 | 2625.293 | 2625.293 | 2625.293 |
Power Loss | [ W ] | 150.6 | 301.2 | 451.7 | 602.3 |
Resistance (Line toLine) | [ Ω ] | 0.52 | 1.05 | 1.57 | 2.09 |
Inductance (Line toLine) | [ mH ] | 1.92 | 3.84 | 5.75 | 7.67 |
Force Constant (Kf) | [ N/Arms ] | 21.65 | 43.95 | 64.95 | 88.55 |
Back EMF Constant (Ke) | [ V/(m/sec)] | 7.29 | 14.58 | 21.87 | 29.16 |
Motor Constant | [ N/W^½ ] | 17.6 | 35.2 | 52.9 | 70.5 |
Electrical Time Constant | [ msec ] | 3.69 | 3.66 | 3.66 | 3.67 |
POLE Pitch | [ mm ] | 84.0 | 84.0 | 84.0 | 84.0 |
Normal Force | [ N ] | 0 | 0 | 0 | 0 |