Application
It is the equipment to measure relative leveling in LCD, semiconductors and high-precision areas.
Features
- Optimization solution for leveling CVD equipment
- Minimized influence of external noise
- Simple Layout
- High precision/ low noise
- User-friendly user interface by dedicated HMI
- Wide temperature range( < 85°)
Technical Data
- Power : AC100V ~240V, 50/60Hz, 1.8A
- Using Temperature: At or Below 65 ℃ (212 ℉)
- Measurement range: 700 ~ 1010 mils [17.780 ~ 25.654 mm]
- Precision : ± 1 um